Attention: 1. For installation, use screws with a tensile strength of greater than 85kg/mm2 (Available upon purchase). 2. Inlet O-Ring must fully comply with GB1325-76 Standards. 3. Notes For Plug Use a) Remove the hollow crew from inside the cover, tighten it again after wire is connected to the base. b) A rubber ring is provided at cable entrance, the plug wiring will be tightly clamped when the threaded cover is tightened. (Note: 3-wire cable should be used for connection)
Technical specification
|
Model |
BMF45P1-50/1.4 |
BMF45P1-90/1.4 |
| Rated Current (mA) |
0.7 |
0.7 |
| Rated Attraction Force (N) |
50 |
90 |
| Rated Travel (mm) |
1.4 |
1.4 |
| Force Hysteresis (%) |
|
2 |
| Current Hysteresis (%) |
|
2 |
| Nominal Fluid Pressure (MPa) |
|
10 |
Model description
External dimensions |